  "version": "2026-11-03-local-review-v4.1-locator",
  "fps": 30,
  "chapters": [
    {
      "id": "prepare",
      "title": "安装前，先确认",
      "subtitle": "停机 · 泄压 · 核对型号",
      "duration": 22,
      "steps": [
        "关闭气源，确认完全泄压",
        "核对管材、接头与配套卡板",
        "切割与钻孔前做好防护"
      ],
      "narration": "安装或改动管路前，先关闭气源，确认完全泄压。核对管材、接头和配套卡板，切割与钻孔时做好个人防护。本片以 TP 二十五为例，演示结构和顺序。",
      "source": "说明书第 3、9 页；TP25 真实 CAD",
      "start": 0,
      "cues": [
        {
          "start": 0.8,
          "end": 7.162,
          "text": "安装或改动管路前，先关闭气源，确认完全泄压。"
        },
        {
          "start": 7.412,
          "end": 14.689,
          "text": "核对管材、接头和配套卡板，切割与钻孔时做好个人防护。"
        },
        {
          "start": 14.939,
          "end": 20.132,
          "text": "本片以 TP 二十五为例，演示结构和顺序。"
        }
      ]
    },
    {
      "id": "pipe",
      "title": "管端准备",
      "subtitle": "切管 → 去毛刺 → 清屑 → 润滑",
      "duration": 24,
      "steps": [
        "按确认尺寸切管，保持切口整洁",
        "去除毛刺，清净管内外铝屑",
        "按适用工艺润滑，保护密封圈"
      ],
      "narration": "按确认的尺寸切管。去除管端毛刺，并清理管内外铝屑。按适用工艺润滑管内壁和接头，保护密封圈。这里的切口与工具动作是示意，设计中心线长度不能直接当作下料尺寸。",
      "source": "说明书第 4 页；切口与工具为教学示意",
      "start": 22,
      "cues": [
        {
          "start": 0.8,
          "end": 3.604,
          "text": "按确认的尺寸切管。"
        },
        {
          "start": 3.854,
          "end": 8.312,
          "text": "去除管端毛刺，并清理管内外铝屑。"
        },
        {
          "start": 8.562,
          "end": 14.139,
          "text": "按适用工艺润滑管内壁和接头，保护密封圈。"
        },
        {
          "start": 14.389,
          "end": 22.41,
          "text": "这里的切口与工具动作是示意，设计中心线长度不能直接当作下料尺寸。"
        }
      ]
    },
    {
      "id": "straight",
      "title": "直通：两管同轴连接",
      "subtitle": "先插接，再装外侧卡板",
      "duration": 31,
      "steps": [
        "两根管与接头轴线对齐",
        "保护密封圈，分别沿接口插接",
        "卡板进入燕尾槽，按工艺紧固"
      ],
      "narration": "直通连接时，先对齐两根管和接头的轴线。将润滑后的接头分别插入管内，保护密封圈。画面为几何配合示意，现场到位判据需要厂家确认。再把配套卡板装入燕尾槽，按确认版安装手册紧固。分解位移不表示实际装入轨迹。",
      "source": "说明书第 4–5 页；625021 / 625500 真实 CAD",
      "start": 46,
      "cues": [
        {
          "start": 0.8,
          "end": 6.078,
          "text": "直通连接时，先对齐两根管和接头的轴线。"
        },
        {
          "start": 6.328,
          "end": 11.625,
          "text": "将润滑后的接头分别插入管内，保护密封圈。"
        },
        {
          "start": 11.875,
          "end": 18.142,
          "text": "画面为几何配合示意，现场到位判据需要厂家确认。"
        },
        {
          "start": 18.392,
          "end": 24.715,
          "text": "再把配套卡板装入燕尾槽，按确认版安装手册紧固。"
        },
        {
          "start": 24.965,
          "end": 28.603,
          "text": "分解位移不表示实际装入轨迹。"
        }
      ]
    },
    {
      "id": "elbow",
      "title": "弯头：两个接口相互垂直",
      "subtitle": "沿各自轴线插接，检查 L 型卡板",
      "duration": 28,
      "steps": [
        "确认两个接口形成 90° 转向",
        "两段管分别沿接口轴线插接",
        "L 型卡板就位，检查全部螺丝"
      ],
      "narration": "弯头的两个接口相互垂直。两段管分别沿各自的接口轴线插入，不要把管口顶在弯头外壳上。安装匹配的 L 型卡板，确认卡板进入燕尾槽，再按确认版安装手册紧固。现场插入到位的判定特征，仍需厂家确认。",
      "source": "说明书第 5–6 页；625022 / 625500 真实 CAD",
      "start": 77,
      "cues": [
        {
          "start": 0.8,
          "end": 4.233,
          "text": "弯头的两个接口相互垂直。"
        },
        {
          "start": 4.483,
          "end": 11.76,
          "text": "两段管分别沿各自的接口轴线插入，不要把管口顶在弯头外壳上。"
        },
        {
          "start": 12.01,
          "end": 20.396,
          "text": "安装匹配的 L 型卡板，确认卡板进入燕尾槽，再按确认版安装手册紧固。"
        },
        {
          "start": 20.646,
          "end": 25.923,
          "text": "现场插入到位的判定特征，仍需厂家确认。"
        }
      ]
    },
    {
      "id": "tee",
      "title": "三通：主管相对，支口垂直",
      "subtitle": "三根管分别对齐三个接口",
      "duration": 26,
      "steps": [
        "先认清两个相对的主管接口",
        "支管沿垂直接口插接",
        "两侧配套卡板就位并检查紧固"
      ],
      "narration": "三通先辨认主管和支管。两个相对的接口连接主管，垂直接口连接支管。三根管分别对齐后插接，再装配两侧卡板并检查紧固。三通会连接三段管；它和连续主管上的平接取气，结构不同。",
      "source": "实物装配参考及 625023 / 625500 CAD；步骤待工程审核",
      "start": 105,
      "cues": [
        {
          "start": 0.8,
          "end": 4.113,
          "text": "三通先辨认主管和支管。"
        },
        {
          "start": 4.363,
          "end": 10.046,
          "text": "两个相对的接口连接主管，垂直接口连接支管。"
        },
        {
          "start": 10.296,
          "end": 16.903,
          "text": "三根管分别对齐后插接，再装配两侧卡板并检查紧固。"
        },
        {
          "start": 17.153,
          "end": 24.485,
          "text": "三通会连接三段管；它和连续主管上的平接取气，结构不同。"
        }
      ]
    },
    {
      "id": "locator",
      "title": "卡板定位器：选孔、贴靠、标记",
      "subtitle": "先用定位器，再装平接套件",
      "duration": 33,
      "steps": [
        "按管径选择对应的定位孔",
        "折边贴靠管材基准边，保持贴合",
        "定位孔位并标记接头安装位置"
      ],
      "narration": "平接开孔之前，先使用钻孔定位卡板。根据管径选择对应的定位孔，让折边贴靠管材基准边，并保持贴合。通过定位孔确定孔位，再标记接头安装位置。移开定位卡板后，按确认工艺完成开孔和清理。它用于辅助定位，不是留在管路上的紧固卡板。",
      "source": "用户提供钻孔器 version 2 STEP；2023 说明书第 7 页与原安装视频操作参考",
      "start": 131,
      "cues": [
        {
          "start": 0.8,
          "end": 5.763,
          "text": "平接开孔之前，先使用钻孔定位卡板。"
        },
        {
          "start": 6.013,
          "end": 14.09,
          "text": "根据管径选择对应的定位孔，让折边贴靠管材基准边，并保持贴合。"
        },
        {
          "start": 14.34,
          "end": 19.792,
          "text": "通过定位孔确定孔位，再标记接头安装位置。"
        },
        {
          "start": 20.042,
          "end": 25.804,
          "text": "移开定位卡板后，按确认工艺完成开孔和清理。"
        },
        {
          "start": 26.054,
          "end": 31.407,
          "text": "它用于辅助定位，不是留在管路上的紧固卡板。"
        }
      ]
    },
    {
      "id": "outlet",
      "title": "平接取气：主管保持连续",
      "subtitle": "定位开孔 → 清屑 → 对位 → 卡紧",
      "duration": 31,
      "steps": [
        "用定位工具对准管材平面中心",
        "按对应型号开孔，去毛刺、清屑",
        "取气板对准孔位，卡槽定位紧固"
      ],
      "narration": "平接取气时，管道本身不切断。先用定位工具对准管材平面的中心，按对应型号的确认版安装手册开孔。去除毛刺并清理铝屑，再把取气板对准孔位，卡板进入燕尾槽后紧固。画面中的开孔标记不表示孔径，实际数值需要核对工艺版本。",
      "source": "说明书第 7 页；1080P 视频约 01:35；625604 CAD",
      "start": 164,
      "cues": [
        {
          "start": 0.8,
          "end": 4.968,
          "text": "平接取气时，管道本身不切断。"
        },
        {
          "start": 5.218,
          "end": 13.355,
          "text": "先用定位工具对准管材平面的中心，按对应型号的确认版安装手册开孔。"
        },
        {
          "start": 13.605,
          "end": 21.701,
          "text": "去除毛刺并清理铝屑，再把取气板对准孔位，卡板进入燕尾槽后紧固。"
        },
        {
          "start": 21.951,
          "end": 28.723,
          "text": "画面中的开孔标记不表示孔径，实际数值需要核对工艺版本。"
        }
      ]
    },
    {
      "id": "check",
      "title": "完成连接，还要检查",
      "subtitle": "复紧检查 → 清理 → 保压 → 记录",
      "duration": 36,
      "steps": [
        "复紧检查，核对安全顶丝",
        "按批准流程清理、充气保压测试",
        "检查泄漏及异常，先泄压再处理"
      ],
      "narration": "完成连接后，复紧检查，并核对需要锁紧的安全顶丝。原视频还展示了预通气清理和充气保压测试，这些操作应由适任人员按批准方案执行。检查泄漏和异常变形，记录检验结果。发现异常，先泄压再处理。压力、时长、允许压降和清理方式，需要按型号确认。",
      "source": "说明书第 9 页；1080P 收尾段；验收流程待工程审核",
      "start": 195,
      "cues": [
        {
          "start": 0.8,
          "end": 7.532,
          "text": "完成连接后，复紧检查，并核对需要锁紧的安全顶丝。"
        },
        {
          "start": 7.782,
          "end": 17.413,
          "text": "原视频还展示了预通气清理和充气保压测试，这些操作应由适任人员按批准方案执行。"
        },
        {
          "start": 17.663,
          "end": 22.396,
          "text": "检查泄漏和异常变形，记录检验结果。"
        },
        {
          "start": 22.646,
          "end": 26.354,
          "text": "发现异常，先泄压再处理。"
        },
        {
          "start": 26.604,
          "end": 33.556,
          "text": "压力、时长、允许压降和清理方式，需要按型号确认。"
        }
      ]
    }
  ],
  "total": 231
}